Product Details:
|
Name Of Product: | Oriana Urine Analyzer (Medium Speed), AUR-300 Easy Visually Interpretation Urine Analysis Solution | Principle: | Photoelectric Colorimetry |
---|---|---|---|
Specimen: | Urine | Certificate: | CE |
Reading Time: | 1 Minute | Storage Temperature: | 2-30°C |
Shelf Life: | 2 Years | Feature: | Easy Operations For High-efficiency |
Pack: | 1 Unit | Dimensions(L/W/H):: | 253*237*171 Mm |
Weight: | 2.6Kg | ||
High Light: | AUR-300 Urine Test Solution,AUR-300 Oriana urine analysis machine,Oriana urine test analyzer AUR-300 |
Oriana Urine Analyzer (Medium Speed), AUR-300 Easy visually interpretation Urine Analysis Solution
Urine Analyzer is a semi-quantitative assessment of urine by using dry chemical methods. According to the principle of photoelectric colorimetry, urine analyzer is used to evaluate the content of biochemical components in the urine through the change of color caused by the reaction of the reagent and urine biochemical components. Urine Analyzer reads Urinalysis Reagent Strips. It stores results and prints reports without the need of special training.
Name Of Product: | Oriana Urine Analyzer (Medium Speed), AUR-300 Easy Visually Interpretation Urine Analysis Solution |
Specimen: | Urine |
Reading Time: | 1 Minute |
Shelf Life: | 2 Years |
Pack: | 1 Unit |
Weight: | 2.6Kg |
Principle: | Photoelectric Colorimetry |
Certificate: | CE |
Storage Temperature: | 2-30掳C |
Feature: | Easy Operations For High-efficiency |
Dimensions(L/W/H):: | 253*237*171 Mm |
Technical Specifications
Principle: Photoelectric Colorimetry Testing Speed : 60 tests/hour (Single test) ; 120 tests/hour (Continuous test) Data Memory: 10,000 Results Strip Incubation Time: 1 minute Light Wavelength: 470nm, 525 nm and 625 nm Display : 192*64 LCD screen Printer: Built-in thermal printer Connectivity: RS232 port ,USB 2 ports Working Condition: 10-30℃, RH≤ 80% , 76-106kPa Working Voltage: AC 100-240V, 50/60Hz Weight: 2.6Kg Dimensions(L/W/H): 253*237*171 mm Compatibility : LIS, HIS |
●ACR (Albumin / Creatinine Ratio) Available! ● Built-in Thermal Printer for Instant Printing ● Comprehensive Range of Test Menu ●Easy Operations for High-efficiency ●Testing Up to 14 Parameters in One Go ●LIS / HIS Compatibility for Better Patient Care |
OrianaTM Urine Analyzer
Great Combination of High Performance and Economy
Intended Use
OrianaTM Urine Analyzer is a semi- quantitative assessment of urine by using dry chemical methods.
According to the principle of photoelectric colorimetry, urine analyzer is used to evaluate the content of biochemical components in the urine through the change of color caused by the reaction of the reagent and urine biochemical components.
Scope of Application
OrianaTM Urine Analyzer works with certain urinalysis reagents strips manufactured by Hangzhou Alltest Biotech CO., Ltd. for the semi-quantitative detection of following analytes in urine:
Abbr. | Parameter | Abbr. | Parameter | Abbr. | Parameter |
ASC | Ascorbic Acid | LEU | Leukocytes | CRE | Creatinine |
BIL | Bilirubin | NIT | Nitrite | PRO | Protein |
BLO | Blood | pH | pH | URO | Urobilinogen |
GLU | Glucose | SG | Specific Gravity | CA | Calcium |
KET | Ketone | ALB | Microalbumin |
It's for in vitro diagnosis professional use and use at Point of Care only. It may be used in central laboratories of medical institutions, outpatient or emergency departments, clinical departments or medical services (such as community health centers), or medical center, etc. It can also be used in research laboratories.
Technical Specification
Specification | Technical Parameters | ||||
Testing Principles | Through reflection photometer to evaluate the color change of urinalysis strip, then calculate the concentration of related items and output semi-quantitative results | ||||
Testing Wave Length | 470nm,525nm,625nm | ||||
Testin Seed | 120PCS(High Speed, Continuous),60 PCS(Low Speed, Single-Step) | ||||
Stray light | Relative intensity ≤ 1% | ||||
Linearity | Linear correlation coefficient ≥0.995 | ||||
Repeatability | Coefficient of variation CV≤1% | ||||
Stability | During 8 hours of operation, Coefficient of variation CV≤1% | ||||
LCD Screen | 240x64 dot-matrix LCD | ||||
Printer | Thermal Printer | ||||
USB x 2 | Connected to external printer, barcode reader(Software in processing ) | ||||
Communication Port | RS-232C DB9 male 9600,19200,38400,57600, 115200bps Start 1 bit , data 8 bit; stop 1 bit, odd parity |
||||
Working Power | Wide power supply input AC100-240V 50/60Hz±1Hz | ||||
Fuse | ф5mm×20mm,T2AL250V | ||||
Power | 30VA | ||||
Dimension | 253mm×237mm×171mm | ||||
Weight | 2.6 kg |
Working and Storage Condition
Parameters | Working condition | Storage condition |
Temperature | 10℃~30℃ | -20℃~50℃ |
Relative Humidity | ≤80% | ≤93% |
Atmospheric Pressure | 76-106Kpa | 76-106Kpa |
Working Condition | Stable Table, avoid of direct strong light and strong electromagnetic interference source |
Clean, Ventilative, Stable |
Ca.No. | Product Description | Pack |
AUR-300 | OrianaTM Urine Analyzer | 1T |
Contact Person: Mrs. Selina