Send Message
Home ProductsFluorescence Immunoassay Analyzer

Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel

Certification
China Hangzhou AllTest Biotech CO.,LTD certification
Customer Reviews
We recently started selling your HCG tests via our Australian partner and have been very impressed with the quality and consistency of the tests. They seem to be superior to our current manufacturer and we also know that you are far more reliable in terms of production times and communication.

—— One customer from Europe

We would like to explore the possibility of switching our HCG tests over to you. We have been reluctant in the past to move everything over to you as it makes us very reliant on you. However, we have always found you to be by far the most reliable of all our Chinese manufacturers and so we feel comfortable strengthening our partnership further

—— One customer from Europe

I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

As the old customer of AllTest since 2009, we should thank the great work have been done by AllTest to support us gain more market share and profit

—— Mr Robin Seifert Germany

I'm Online Chat Now

Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel

Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel
Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel

Large Image :  Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel

Product Details:
Place of Origin: China
Brand Name: AllTest
Certification: qualified
Model Number: AFR-600
Payment & Shipping Terms:
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 1 Unit
Supply Ability: 10 M tests/month

Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel

Description
Product: Novatrend Plus Dry-type Fluorescence Immunoassay Analyzer (Single Channel), Fluorescence Immunoassay Analyzer Cat No.: AFR-600
Test Method: Fluorescence Immunoassay Test Format: Cassette
Measurement: Quantitative, Qualitative Reading Time: <20 Seconds
Display: 7"LCD Touch Color Screen Memory: 10000 Records
Dimensions(L*W*H): 220*190*120mm Weight: 2Kg
Storage Conditions: 5~45 ℃,RH ≤85% Working Conditions: 10~30℃,RH≤85%
Period Of Validity: 5 Years
High Light:

Dry Type Fluorescence Immunoassay Analyzer

,

Fluorescence Immunoassay Analyzer Single Channel

Novatrend Plus Dry-Type Fluorescence Immunoassay Analyzer (Single Channel), Fluorescence Immunoassay Analyzer

 

Test Method Fluorescence Immunoassay
Test Format Cassette
Measurement Quantitative, Qualitative
Reading Time <20 Seconds
Display 7"LCD touch color screen
Memory 10000 records
Dimensions(L*W*H) 220*190*120mm
Weight 2Kg
Storage Conditions 5~45 ℃,RH ≤85%
Working Conditions 10~30℃,RH≤85%
Printer Built-in thermal printer
Power Source DC24V,2.5A,60W MAX
Compatibility LIS
Scanner Laser barcode scanner with USB port
Connectivity

USB2 ports, LAN port, RS232 COM port

(WLAN is optional functions)

Period of Validity 5 Years

 

Novatrend Plus Dry-type Fluorescence Immunoassay Analyzer (Single Channel), Fluorescence Immunoassay Analyzer

 

Intended Use
 
Novatrend Plus+TM Dry-type Fluorescent Immunoassay Analyzer (Single Channel) is a dry fluorescent immunoassay strip detection system based on photoelectric detection principle, which needs reagents based on fluorescent immunoassay principle. Analyzer uses the specificity of in vitro diagnostic testing unit, including inflammatory markers, tumor markers, markers, diabetes, kidney disease markers, cardiacmarkers, blood coagulation markers, endocrinology markers and markers of autoimmune and infectious disease markers, samples for testing to human body, providing quantitative or qualitative test results. Fluorescence immunoanalyzer has the advantages of high accuracy, strong stability and fast results.
 
Application
 
The instrument is used by in vitro diagnosis professionals and nursing points, and can be used in central laboratories, outpatient and emergency departments, clinical departments or medical service institutions (such as community health centers), medical centers, etc. It can also be used in research laboratories. Novatrend Plus+TM Dry-type Fluorescent Immunoassay Analyzer (Single Channel) can only be used for in vitro diagnostic reagents produced by Hangzhou AllTest Biotechnology Co., LTD., according to the instructions of the specific kit.
 
Installation and Trial Run
 
The first installation confirmation of the instrument must be approved by the company's authorized technical engineer or agent.
 
Please place the instrument on a flat table with sufficient area and no vibration. The bearing capacity of the table is more than 18kg and the platform area is > 70cm*50cm; Keep a sufficient distance between the device and the wall. Do not place the device in a position where it is difficult to operate and disconnect the device. Take out the power cord, connect one end of the device to the power interface on the rear panel, and connect the other end to the power supply socket. There must be good grounding protection, and the grounding resistance should meet the relevant national standards. There should be independent and reliable ground cables in the room, and they should not share the same line with high-power electrical equipment.
 
Transportation
 
Temperature:-30℃~55℃;
Relative humidity: ≤85%;
Environment: no toxic gases, flammable, explosive substances and corrosive gases are allowed. Attention should be paid to moistureproof, shock and severe vibration during transportation.
 
Operating Principle
 
This analyzer excites the reacted test cassette which is a based on europium microspheres marked fluorescence immunoassay with a UV LED light source, then collects, analyzes and calculates the signal from the test card, and gives the test result.
 
Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel 0
 
1:Touch screen;2:Reagent strip socket;3:Built-in Thermal Printer
1. Touch screen:Display instrument software interface and other information
2. Reagent strip socket:Reagent load
3. Built-in Thermal Printer:Used to print test results
 
Novatrend Plus Dry Type Fluorescence Immunoassay Analyzer Single Channel 1
1:Power switch; 2:power interface; 3:LAN port;
4:USB port; 5:COM port; 6:CODE socket
1. Power switch:Power on or off the instrument
2. power interface:Connect the power cable, as shown in Fig 3.2.3
3. LAN port:Connecting network cables
4. USB port:Used for upgrading software, exporting data or connecting scan gun with instrument USB disk
5. COM port:Used to transmit data
6. CODE socket:Insert code and read code data
 
Precautions for Installation and Commissioning
  • Please choose a suitable place according to the environment, power supply and space requirements.
  • The connection between the power cord and the instrument must be safe, firm and in good contact.
  • After confirming the connection, you can start the machine.
  • When using, avoid direct glare as far as possible, and prohibit non-professional maintenance personnel to open the instrument.
  • Please do not put water containers or metal objects on the instrument. If water or metal objects fall into the instrument accidentally, unplug the power plug in time and cut off the power supply. Find a professional to deal with it.
  • If there is smoke, abnormal sound, or peculiar smell, disconnect the power supply and contact professional personnel in time.
  • Please avoid the impact of external force on the instrument.
  • When the instrument is working, do not put your hand on the working area of the instrument to avoid injury.
  • Ensure that the device is powered off and the power adapter is removed. Do not move the device when the power is on

 

Product Advantages:

 

Large Memory

(Capable of storing 10,000result records)

High Accuracy

(Stringent Quality Control Monitoring &System Check Function)

User-Friendly

(Simple Plug& Play Operation, Big LCD Touch Screen)

Easy Operation

(Less Training Required)

Ideal for Emergency Situations

(Lightweight, Small Size and Easy Operation)

Time-saving

(Reading Time less than 20 Seconds)

Get Printing Test Reports Instantly

(Built-in Thermal Printer )

Contact Details
Hangzhou AllTest Biotech CO.,LTD

Contact Person: Mrs. Selina

Tel: 86-13989889852

Send your inquiry directly to us (0 / 3000)