Send Message
Home News

company news about Procalcitonin (PCT) Test Cassette

Certification
China Hangzhou AllTest Biotech CO.,LTD certification
Customer Reviews
We recently started selling your HCG tests via our Australian partner and have been very impressed with the quality and consistency of the tests. They seem to be superior to our current manufacturer and we also know that you are far more reliable in terms of production times and communication.

—— One customer from Europe

We would like to explore the possibility of switching our HCG tests over to you. We have been reluctant in the past to move everything over to you as it makes us very reliant on you. However, we have always found you to be by far the most reliable of all our Chinese manufacturers and so we feel comfortable strengthening our partnership further

—— One customer from Europe

I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

As the old customer of AllTest since 2009, we should thank the great work have been done by AllTest to support us gain more market share and profit

—— Mr Robin Seifert Germany

I'm Online Chat Now
Company News
Procalcitonin (PCT) Test Cassette
Latest company news about Procalcitonin (PCT) Test Cassette
A rapid test for measuring Procalcitonin (PCT) in whole blood /serum /plasma with the use of Fiatest TM fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.
 
 

Application:

 

The PCT Test Cassette (Whole Blood/Serum/Plasma) is based on Fluorescence immunoassay for the quantitative detection of human Procalcitonin in whole blood, serum or plasma as an aid in the diagnosis of inflammatory conditions.

 

Description:

 

Procalcitonin (PCT) is a small protein that comprises 116 amino acid residues with a molecular weight of approximately 13 kDa which was first described by Moullec et al. in 1984. PCT is produced normally in C-cells of the thyroid glands. In 1993, the elevated level of PCT in patients with systemic infection of bacterial origin was reported and PCT is now considered to be the main marker of disorders accompanied by systemic inflammation and sepsis. The diagnostic value of PCT is important due to the close correlation between PCT concentration and the severity of inflammation. It was shown that “inflammatory” PCT is not produced in C-cells. Cells of neuroendocrine origin are presumably the source of PCT during inflammation.

 

 

How to use?

 

Refer to Fiatest TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be in room temperature.
1. Turn on the Analyzer power. Then according to the need, select “Standard test” or “Quick test” mode.
2. Take out the ID card and insert it into the Analyzer ID Card Slot.
3. Serum or plasma: Pipette 50 μL serum or plasma into the buffer tube, mix the specimen and the buffer well.
Whole blood: Pipette 75 μL whole blood into the buffer tube; mix the specimen and the buffer well.
4. Pipette 75 μL diluted sample into the sample well of the cassette. Start the timer at the same time.
5. There are two test modes for Fiatest TM Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode. Please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyzer for details.
“Quick test” mode:After 15 minutes of adding sample,Insert the test cassette into the Analyzer and click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.
“Standard test” mode:Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time. The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.
latest company news about Procalcitonin (PCT) Test Cassette  0
 
INTERPRETATION OF RESULTS
Results read by Fiatest TM Fluorescence Immunoassy Analyzer.
The result of tests for PCT is calculated by Fiatest TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyze.
Linearity range of Fiatest TM PCT is 0.1-50 ng/mL.
Reference range: <0.1ng/ml.

 

Catalogue Number Item Name Sample Test Range KIT size
FI-PCT-402 PCT Test Cassette WB/S/P 0.1~50 ng/ml

10T/25T

 