Send Message
Home ProductsUrine Test Solution

Portable Low Speed Urine Test Solution , EZCHEK Urine Chemistry Analyzer

Certification
China Hangzhou AllTest Biotech CO.,LTD certification
Customer Reviews
We recently started selling your HCG tests via our Australian partner and have been very impressed with the quality and consistency of the tests. They seem to be superior to our current manufacturer and we also know that you are far more reliable in terms of production times and communication.

—— One customer from Europe

We would like to explore the possibility of switching our HCG tests over to you. We have been reluctant in the past to move everything over to you as it makes us very reliant on you. However, we have always found you to be by far the most reliable of all our Chinese manufacturers and so we feel comfortable strengthening our partnership further

—— One customer from Europe

I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

As the old customer of AllTest since 2009, we should thank the great work have been done by AllTest to support us gain more market share and profit

—— Mr Robin Seifert Germany

I'm Online Chat Now

Portable Low Speed Urine Test Solution , EZCHEK Urine Chemistry Analyzer

Portable Low Speed Urine Test Solution , EZCHEK Urine Chemistry Analyzer
Portable Low Speed Urine Test Solution , EZCHEK Urine Chemistry Analyzer

Large Image :  Portable Low Speed Urine Test Solution , EZCHEK Urine Chemistry Analyzer

Product Details:
Place of Origin: China
Brand Name: ALLTEST
Certification: CE
Model Number: AUR-200
Payment & Shipping Terms:
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 100T
Delivery Time: 2-4 Weeks
Payment Terms: L/C, T/T
Supply Ability: 10 M tests/month

Portable Low Speed Urine Test Solution , EZCHEK Urine Chemistry Analyzer

Description
Name Of Product: EZCHEK Urine Analyzer (Portable/Low Speed) Result In 1 Minutes, Urine Analysis Solution Principle: Photoelectric Colorimetry
Specimen: Urine Certificate: CE
Reading Time: 1 Minute Storage Temperature: 2-30°C
Shelf Life: 2 Years Feature: High Sensitivity, Specificity, And No Cross Reactivity
Pack: 1 Unit Weight:: 600g
Dimensions(L/W/H):: 200*137*52 Mm
High Light:

Low Speed Urine Test Solution EZCHEK

,

Portable automated urine analyser EZCHEK

,

EZCHEK Urine Chemistry Analyzers

EZCHEK Urine Analyzer (Portable/Low Speed) Result in 1 minutes, Urine Analysis Solution

 

Urine Analyzer is a semi-quantitative assessment of urine by using dry chemical methods. According to the principle of photoelectric colorimetry, urine analyzer is used to evaluate the content of biochemical components in the urine through the change of color caused by the reaction of the reagent and urine biochemical components. Urine Analyzer reads Urinalysis Reagent Strips. It stores results and prints reports without the need of special training.

 

Name Of Product: EZCHEK Urine Analyzer (Portable/Low Speed) Result In 1 Minutes, Urine Analysis Solution
Specimen: Urine
Reading Time: 1 Minute
Shelf Life: 2 Years
Pack: 1 Unit
Dimensions(L/W/H):: 200*137*52 Mm
Principle: Photoelectric Colorimetry
Certificate: CE
Storage Temperature: 2-30 ℃ 
Feature: High Sensitivity, Specificity, And No Cross Reactivity
Weight:: 600g

 

Features:

 

Technical Specifications

 

Principle: Photoelectric Colorimetry

Testing Speed : 60 tests/hour

Data Memory: 10,000 Results

Strip Incubation Time: 1 minute

Light Wavelength: 470nm, 525nm and 625 nm

Display : 3.5” LCD touch screen

Printer: Built-in thermal printer

Connectivity: RS232 port ,USB 2 ports

Working Condition: 10-30℃, RH≤ 80% , 76-106kPa

Working Voltage: AC 100-240V, 50/60Hz,

DC 5.85V±0.45V (AA×4)

Weight: 600g

Dimensions(L/W/H): 200*137*52 mm

 

●ACR (Albumin / Creatinine Ratio) Available!

●Comprehensive Range of Test Menu

●Built-in Battery Available for STAT Usage

●Testing Up to 14 Parameters in One Go

●Light Weight for Easy Mobility

●Built-in Thermal Printer for Instant Printing

●Touch Screen Operation with Big Screen for Easy Operation

 

 

Ultrona Urine Chemistry Analyzer Offering Accurate And Reliable Automation In Urinaly

 

UltronaTM Urine Analyzer
Offering Reliable Automation in Urinalysis Testing


 

Intended Use
UltronaTM Urine Analyzer is a semi- quantitative assessment of urine by using dry chemical methods.
According to the principle of photoelectric colorimetry, urine analyzer is used to evaluate the content of biochemical components in the urine through the change of color caused by the reaction of the reagent and urine biochemical components.
Scope of Application
UltronaTM Urine Analyzer works with certain urinalysis reagents strips manufactured by Hangzhou Alltest Biotech CO., Ltd. for the semi-quantitative detection of following analytes in urine:
 
 
Abbr. Parameter Abbr. Parameter Abbr. Parameter
ASC Ascorbic Acid LEU Leukocytes CRE Creatinine
BIL Bilirubin NIT Nitrite PRO Protein
BLO Blood pH pH URO Urobilinogen
GLU Glucose SG Specific Gravity ALB Microalbumin
KET Ketone CA Calcium    
 
It's for in vitro diagnosis professional use and use at Point of Care only. It may be used in central laboratories of medical institutions, outpatient or emergency departments, clinical departments or medical services (such as community health centers), or medical center, etc. It can also be used in research laboratories.
 
Technical Specification
 
Specification Technical Parameters
Testing Principles Through reflection photometer to evaluate the color change of urinalysis strip, then calculate the concentration of related items and output semi-quantitative results
Testing Wave Length 470nm,525nm,625nm
Testin Seed 500 samples / hour
Stray light Relative intensity ≤ 1%
Linearity Linear correlation coefficient ≥0.995
Repeatability Coefficient of variation CV ≤ 1%
Stability During 8 hours of operation, Coefficient of variation CV ≤ 1%
Output Options LCD display, serial port output,
Embedded 57mm thermal printer (English/Chinese),
External parallel dot matrix printer,(English/Chinese)
LCD Screen 240x64 dot-matrix LCD
Report Storage Stores up to 2000 sets of results.
External Ports RS-232C connected with PC
25 pin centronics port which can driver a dot external printer
Working Voltage AC100-240V 50/60Hz
Power ≤ 45 w
Dimension 200*137*52 mm
Weight 6 kg
 
 
 
 
 